Introduction
Passivation in electrochemical storage refers to the formation of a microscopic protective layer on a battery’s active materials—most notably the anode—during prolonged storage. To prevent this layer from thickening and rendering the battery unusable over time, de-passivation is used. This process involves periodically discharging the battery with a small amount of current to keep it active.
The Motsai eBook, A Deep Study About Depassivation of Sodium Battery and Lithium Primary Battery, offers an in-depth examination of these mechanisms, featuring experimental data and practical examples across various cell types. Leveraging advanced battery test-bed facilities, Motsai Research continually analyzes diverse chemistries to translate deep electrochemical understanding into improved system-level performance. Building on these insights, the following sections introduce a practical electrical circuit designed to automate the de-passivation process.
Methodology
Using a microprocessor controller to activate a derivation circuit, so to discharge the battery in a small current after a certain amount of time.

De-passivation Process:
- The MCU transmits periodic signals at a controlled frequency.
- When the MCU outputs a rising signal, the derivative circuit generates a positive voltage, Vg. The pulse duration (signal width) depends on the time constant T=R1C. This activates the MOSFET, initiating the active discharging process.
- When the MCU outputs zero or a constant signal, the capacitor blocks the circuit. Vg drops after time T, disconnecting the MOSFET and halting the discharge. Component selection depends on the required time constant, battery capacity, and other factors. We examine two typical primary batteries as examples: the ER34615 (19Ah) and the ER14505 (2.6Ah).
Traditionally, de-passivation relies on a continuous small current to keep the battery active. This “balance current” is applied continuously throughout the battery’s storage life—typically 50µA for the ER34615 and 15µA for the ER14505 [2]. A continuous 50µA discharge would deplete an ER34615 in 43.38 years; after 5 years of storage, approximately 88% of its usable energy remains. For the ER14505, a 15µA continuous discharge lasts 19.79 years, leaving roughly 75% capacity after 5 years.
However, continuous discharging is not an optimal solution under any circumstance. Energy is wasted unnecessarily, as passivation develops gradually over time. Consequently, the de-passivation process should be periodic, tailored to the actual rate of passivation.
Conclusion
This designed circuit provides a tunable, periodic de-passivation solution. Circuit parameters, the discharge resistor (R2) is calculated based on the required balance current. Since the ER34615 has an open-circuit voltage of 3.6V, achieving a 50µA current requires an R2 value of 72 kΩ. As for the time factors, manufacturers recommend applying a 100–200Ω load for 5–10 seconds to de-passivate a 3.6V primary battery after a month of storage. For a deeply passivated “dead” battery in long-term storage, a 10mA discharge over several hours is usually required.
References
[1] eBook ‘A Deep Study About Depassivation of Sodium Battery and Lithium Primary Battery’, www.motsai.com
[2] lithium-thionyl-chloride-batteries-passivation.pdf, www.zeus.com